DI40001
Address Id
Data Enumerations
| Value | Description |
|---|---|
| Value A01 | Description DB equipment operating hot (signs of overheating) |
| Value A02 | Description Only to be used by SFIC - Service cable currently operating hot |
| Value A03 | Description Defective/weakened fuse carrier |
| Value A04 | Description Physical damage to DB equipment requiring immediate action |
| Value A05 | Description Sign of DB equipment burning, smoking or arcing |
| Value A06 | Description Only to be used by SFIC - Audible sounds of arcing |
| Value A07 | Description Exposed live conductor |
| Value A08 | Description Only to be used by SFIC - Broken fuse carrier - access to live components |
| Value A10 | Description DB earthing issue at existing installation which presents an immediate risk to Customer/MO |
| Value A12 | Description Damaged asbestos component in DB equipment |
| Value A14 | Description Polarity identified as incorrect at DB equipment |
| Value A15 | Description Immediate risk to the public or Customer due to current service position location |
| Value A17 | Description Live unearthed DB metal-encased equipment |
| Value A19 | Description Surface voltage found on plastic cut-out |
| Value B01 | Description Fuse carrier welded in to cut-out base |
| Value B02 | Description Cut-out loose |
| Value B03 | Description Damaged/missing phase barriers in DB equipment |
| Value B04 | Description Damaged/broken cut-out terminal including missing terminal screws |
| Value B05 | Description Non-withdrawable fuse by design |
| Value B06 | Description Only to be used by SFIC - Cut-out unable to accept 16mm² meter tails |
| Value B07 | Description DB equipment issue preventing installation/replacement of meter tails |
| Value B08 | Description Unhinged metal cut-out cover over un-insulated conductors |
| Value B10 | Description Unearthed DB metal-encased equipment |
| Value B11 | Description Cut-out with a fused neutral |
| Value B12 | Description DB owned CT metering equipment issue |
| Value C02 | Description Signs of bitumen compound leaking |
| Value C03 | Description Lower rating fuse or cut-out (less than 60A) |
| Value C06 | Description Metal-encased cut-out |
| Value C07 | Description DB equipment unable to be securely sealed |
| Value C11 | Description Asbestos component identified in DB equipment |
| Value C14 | Description Fed from distribution board - local/remote from meter |
| Value C15 | Description DB cable terminating into DB equipment is VIR/MICC |
| Value C16 | Description DB equipment mounted on asbestos board |
| Value C17 | Description Black plastic cut-out |
| Value C18 | Description Rewireable cut-out fuse |
| Value C19 | Description Single insulated DB conductor (phase or non-PME neutral) |
| Value C20 | Description Missing combined neutral-earth cover on DB equipment |
| Value C21 | Description Non-standard PME connection arrangement |