MM00051

Traditional Meter Technical Details

Local Catalogue Reference
D0150
Message Version
2
Description
Meter Technical Details for Traditional Metering Assets.
Notes
Used for all Non Half Hourly meters for Non-MHHS Metering Points or Traditional Metering Assets for MHHS Metering Points
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00527 Name Traditional Meter Technical Details Source Electricity Smart Meter Equipment Manager Target Smart Data Service Owner Retail Energy Code Company Change selection
Structure
SV00527
Flow structure for SV00527
ID Name Range Level Required
288 MPAN Cores Range: 1-* L1 Mandatory
MPAN Core Mandatory
Effective from Settlement Date {MSMTD} Mandatory
Measurement Class Id Optional
Energisation Status Mandatory
289 SSCs Range: 1-1 L2
Standard Settlement Configuration (SSC) Id Mandatory
Effective from Settlement Date {SCON} Mandatory
Metering System Non Settlement Functionality Code Optional
Effective From Settlement Date {MSNSFC} Optional
762 Metering Point Maintenance History Range: 0-1 L2 Optional
Maintenance Date Mandatory
Nature of Maintenance Mandatory
290 Meter/Retrieval Method Details Range: 0-* L2
Conditions: Meter/Retrieval Method Details

Meter/Retrieval Method Details message collection is Mandatory if a meter is installed at the Metering Point; or, Meter/Retrieval Method Details message collection is Not Present if a meter is not installed at the Metering Point.

Meter ID Mandatory
Meter COP Optional
Meter COP Dispensation Optional
Meter Current Rating Mandatory
Meter Location Mandatory
Manufacturers Make & Type Mandatory
Meter Asset Provider Id Mandatory
Communications Address Optional
Communications Method Optional
Outstation PIN Optional
Outstation COP Optional
Outstation COP Dispensation Optional
Outstation Encryption Key Optional
Outstation Number of Channels Optional
Outstation Password Level 1 Optional
Outstation Type Optional
VT Ratio Optional
Meter Type Mandatory
Date of Meter Installation Optional
Certification Date Optional
Certification Expiry Date Optional
Timing Device Id (Serial Number) Optional
Tele-Switch/Clock Indicator Optional
Retrieval Method Mandatory
Retrieval Method Effective Date Mandatory
291 CT Ratio Range: 0-1 L3
Conditions: CT Ratio

CT Ratio message collection is Mandatory if a Current Transformer exists at the Metering Point; or,CT Ratio message collection is Not Present if a Current Transformer does not exist at the Metering Point.

CT Ratio Mandatory
293 Meter Register Details Range: 1-* L3 Mandatory
Meter Register Id Mandatory
Meter Register Type Mandatory
Measurement Quantity Id Mandatory
Meter Register Multiplier Mandatory
Main/Check Indicator Optional
Number of Register Digits Mandatory
Associated Meter Id Optional
Associated Meter Register Id Optional
295 Meter Channels Range: 0-* L3
Conditions: Meter Channels

Meter Channels message collection is Mandatory if a Half Hourly meter is installed at the Metering Point.

Channel Number Optional
Measurement Quantity Id Optional
Pulse Multiplier Optional
296 Metering System Maintenance History Range: 0-* L3 Optional
Maintenance Date Mandatory
Nature of Maintenance Mandatory
08A Meters Removed Range: 0-* L2
Conditions: Meters Removed

Meters Removed Message Collection cardinality >0 only permissible following a Meter removal event.

Meter ID Mandatory
Date of Meter Removal Mandatory
Meter Asset Provider Id Mandatory