MM00065

Notification of Meter Operator or Data Collector Appointment and Terms

Local Catalogue Reference
D0155
Message Version
1
Description
This is a notification of a new or changed appointment to a metering system and of the contractual terms to be applied
Notes
Required First Scheduled Read Date is an optional field to be used where there is a service level agreement between a Supplier and an Agent which allows the Supplier to specify the Scheduled Read Date. ' Where an AMVLP (Asset Metering Virtual Lead Party) is involved, the MPAN Core must contain an AMSID (Asset Metering System Identifier) and not an MPAN This flow includes Unmetered Supply Requirements. Though all of the address data items included in this flow are defined within the structure as being optional, the address itself is mandatory and must be included in the flow. The use of any individual address item cannot be made mandatory as, in the absence of an agreed address structure for all flows, an address may be constructed from any combination of the Address Line and Postcode items. Postcode should only be omitted if the Post Office has not generated one for the premises. The Supplier may use the Smart CoS Process Indicator to request that the NHHDC or NHH MOP should use the Change of Supplier process for smart meters (as introduced by BSC Modification P302). The Smart CoS Process group is optional to allow Suppliers to make alternative bi'lateral arrangements for requesting their agents to use the smart process. For the avoidance of doubt, unless other arrangements have been agreed between a Supplier and their agents, legacy processes will be followed if the Smart CoS Process group is not populated.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00065 Name Notification of Meter Operator or Data Collector Appointment and Terms Source Electricity Supplier Target Half Hourly Data Collector Owner Balancing and Settlement Code Company Change selection
Structure
SV00065
Flow structure for SV00065
ID Name Range Level Required
315 MPAN Cores Range: 1-* L1
Conditions: MPAN Cores

Please reference Address Population Rules.

MPAN Core Mandatory
Effective from Settlement Date {REGI} Mandatory
Address Line 1 Optional
Address Line 2 Optional
Address Line 3 Optional
Address Line 4 Optional
Address Line 5 Optional
Address Line 6 Optional
Address Line 7 Optional
Address Line 8 Optional
Address Line 9 Optional
Metering Point Postcode Optional
Contract Reference Mandatory
Retrieval Method Mandatory
GSP Group Id Mandatory
320 Reading Cycle Details Range: 1-1 L2 Mandatory
Regular Reading Cycle Mandatory
Required First Scheduled Read Date Optional
316 DC Effective Date Range: 1-1 L2 Mandatory
Effective from Date {DCA} Mandatory
317 MOP Effective Date Range: 1-1 L2 Mandatory
Effective from Date {MOA} Mandatory
318 Agreed Service Details Range: 1-* L2 Mandatory
Service Reference Mandatory
Service Level Reference Mandatory
22L Smart CoS Process Range: 0-1 L2 Optional
Smart CoS Process Indicator Mandatory