MM00107

Selective or Full Refresh of MPAS Details

Local Catalogue Reference
D0204
Message Version
2
Description
The set of data sent to a Supplier following a request for refresh of the details held within MPAS.
Notes
Sub'Groups are retained for Objection Registration and Objection Removal to attach meaning to the data item 'Deemed Received Date' held in these groups. Though all of the address data items included in this flow are defined within the structure as being optional, the address itself is mandatory and must be included in the flow. The Metering Point Address Lines 1'9 and Metering Point Postcode will be in Standard Address Format (SAF). Metering Point Postcode should only be omitted if the Post Office have not allocated one.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00107 Name Selective or Full Refresh of MPAS Details Source Electricity Retail Data Agent Target Electricity Supplier Owner Balancing and Settlement Code Company Change selection
Structure
SV00107
Flow structure for SV00107
ID Name Range Level Required
751 File Sequence Number Range: 1-1 L1 Mandatory
File Sequence Number Mandatory
763 Instruction Details Range: 1-* L2 Mandatory
Instruction Number Mandatory
Instruction Type Mandatory
440 Current MPAS Details Range: 1-* L3
Conditions: Current MPAS Details

Please reference Address Population Rules.

MPAN Core Mandatory
Address Line 1 Optional
Address Line 2 Optional
Address Line 3 Optional
Address Line 4 Optional
Address Line 5 Optional
Address Line 6 Optional
Address Line 7 Optional
Address Line 8 Optional
Address Line 9 Optional
Metering Point Postcode Optional
Metering Point Unique Property Reference Number (UPRN) Null
451 GSP Group Settlement Date Detail Range: 1-* L4 Mandatory
GSP Group Id Mandatory
Effective from Settlement Date {MSGG} Mandatory
450 Line Loss Factor Class/Date Detail Range: 0-* L4 Optional
Line Loss Factor Class Id Mandatory
Distributor Id Mandatory
Effective from Settlement Date {MSLLFC} Mandatory
441 Registration of Supplier Details Range: 0-* L4
Effective from Settlement Date {REGI} Mandatory
Registration Transaction Number Null
Effective to Settlement Date {REGI} Optional
Deemed Received Date Mandatory
669 Objection Registration Range: 0-1 L5 Optional
Deemed Received Date Mandatory
670 Objection Removal Range: 0-1 L5 Optional
Deemed Received Date Mandatory
445 Energisation Status Details Range: 0-* L4 Optional
Energisation Status Mandatory
Effective from Settlement Date {MSES} Mandatory
447 Meter/Timeswitch Details Range: 0-* L4 Optional
Meter Timeswitch Code Mandatory
Meter Timeswitch Code Effective from Date Mandatory
448 Profile Class Settlement Date Detail Range: 0-* L4 Optional
Profile Class Id Mandatory
Effective from Settlement Date {MSPC} Mandatory
449 SSC Detail Range: 0-* L4 Optional
Standard Settlement Configuration (SSC) Id Mandatory
Effective from Settlement Date {SCON} Mandatory
446 Measurement Class Details Range: 0-* L4 Optional
Measurement Class Id Mandatory
Effective from Settlement Date {MSMC} Mandatory
764 Data Aggregator Details Range: 0-* L4 Optional
Data Aggregator Id Mandatory
Data Aggregation Type Mandatory
Effective from Settlement Date {DAA} Mandatory
443 Data Collector Details Range: 0-* L4 Optional
Data Collector Id Mandatory
Data Collector Type Mandatory
Effective from Date {DCA} Mandatory
444 Meter Operator Details Range: 0-* L4 Optional
Meter Operator Id Mandatory
Meter Operator Type Mandatory
Effective from Date {MOA} Mandatory
90H DCC Service Flag Range: 0-* L4 Optional
DCC Service Flag Optional
Effective from Date {DCCF} Optional
91H SMETS Version Range: 0-* L4 Optional
SMETS Version Optional
92H SMSO ID Range: 0-* L4 Optional
Smart Metering System Operator (SMSO) Optional
Effective from Date {SMSO} Optional
93H IHD Install Status Range: 0-* L4 Optional
In Home Display (IHD) Install Status Optional
Effective from Date {IHDI} Optional
47M Related Status Range: 1-* L4 Mandatory
Related MPAN Indicator Mandatory
48M Related MPANs Range: 0-* L5
Conditions: Related MPANs

Related MPANs message collection is Mandatory if Related MPAN Indicator value is Y; or message collection is Not Present if value is N.

Primary MPAN Mandatory
Secondary MPAN Mandatory