MM00109

Instruction(s) to Non Half Hourly or Half Hourly Data Aggregator

Local Catalogue Reference
D0209
Message Version
1
Description
Covers appointment details for Data Aggregator/Data Collector and details of Registrations, Measurement Class, Energisation Status, Line Loss Factor Class, GSP Group, and for NHHDA will include Profile Class/Standard Settlement Configuration.
Notes
The data set of profile classes/standard settlement configurations must never be included when this flow is sent to a HHDA.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00110 Name Instruction(s) to Non Half Hourly or Half Hourly Data Aggregator Source Electricity Retail Data Agent Target Non Half Hourly Data Aggregator Owner Balancing and Settlement Code Company Change selection
Structure
SV00110
Flow structure for SV00110
ID Name Range Level Required
ZPI Instruction File Additional Header Range: 1-1 L1 Mandatory
File Sequence Number Mandatory
ZIN Instruction Number Range: 1-1 L1
Conditions: Instruction Number

If Refresh

Instruction Number Mandatory
Type Code Mandatory
Metering System Id Mandatory
Market Role Null
Participant Id Null
ISD Significant Date Range: 1-1 L1 Mandatory
Significant Date Mandatory
MSH Metering System Header Range: 0-* L1 Optional
Metering System Id Mandatory
SUP Supplier Registration Range: 0-* L2 Optional
Effective from Settlement Date {REGI} Mandatory
Supplier Id Mandatory
DAA Data Aggregator Appointment Range: 0-* L2 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {DAA} Mandatory
Effective to Settlement Date {DAA} Optional
DCA Data Collector Appointment Range: 0-* L2 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Date {DCA} Mandatory
Data Collector Id Mandatory
PSS Profile Class/Standard Settlement Configuration Range: 0-* L2 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {PCSSCR} Mandatory
Profile Class Id Mandatory
Standard Settlement Configuration (SSC) Id Mandatory
MCL Measurement Class Range: 0-* L2 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {MCR} Mandatory
Measurement Class Id Mandatory
EST Energisation Status Range: 0-* L2 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {ESR} Mandatory
Energisation Status Id Mandatory
LLF Line Loss Factor Class Range: 0-* L2 Optional
Effective from Settlement Date {MSLLFC} Mandatory
Distributor Id Mandatory
Line Loss Factor Class Id Mandatory
GGP GSP Group Range: 0-* L2 Optional
Effective from Settlement Date {MSGG} Mandatory
GSP Group Id Mandatory
ZIN Instruction Number Range: 1-* L1
Conditions: Instruction Number

If not Refresh

Instruction Number Mandatory
Type Code Mandatory
Metering System Id Mandatory
Market Role Null
Participant Id Null
ISD Significant Date Range: 1-1 L2 Mandatory
Significant Date Mandatory
SUP Supplier Registration Range: 0-* L3 Optional
Effective from Settlement Date {REGI} Mandatory
Supplier Id Mandatory
DAA Data Aggregator Appointment Range: 0-* L3 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {DAA} Mandatory
Effective to Settlement Date {DAA} Optional
DCA Data Collector Appointment Range: 0-* L3 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Date {DCA} Mandatory
Data Collector Id Mandatory
PSS Profile Class/Standard Settlement Configuration Range: 0-* L3 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {PCSSCR} Mandatory
Profile Class Id Mandatory
Standard Settlement Configuration (SSC) Id Mandatory
MCL Measurement Class Range: 0-* L3 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {MCR} Mandatory
Measurement Class Id Mandatory
EST Energisation Status Range: 0-* L3 Optional
Effective from Settlement Date {REGI} Mandatory
Effective from Settlement Date {ESR} Mandatory
Energisation Status Id Mandatory
LLF Line Loss Factor Class Range: 0-* L3 Optional
Effective from Settlement Date {MSLLFC} Mandatory
Distributor Id Mandatory
Line Loss Factor Class Id Mandatory
GGP GSP Group Range: 0-* L3 Optional
Effective from Settlement Date {MSGG} Mandatory
GSP Group Id Mandatory