MM00156

Advanced Meter Technical Details

Local Catalogue Reference
D0268
Message Version
2
Description
Advanced Meter Technical Details are transferred when there is a change in equipment, configuration or upon change of Agent
Notes
D0268 flow will contain as a minimum six measurement quantity Ids of AI, RI and RE plus three mapped as 'UN', where RI and RE only increment when the site is actively Importing and the 'UN' channels correspond to the Export measurement quantities. Conversely the D0268 for the Active Export MPAN will also have six measurement quantities of AE, RI and RE plus three mapped as 'UN', where RI and RE increment only when the site is actively exporting and the 'UN' channels correspond to the Import measurement quantities
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00159 Name Advanced Meter Technical Details Source Electricity Meter Equipment Manager Target Electricity Meter Equipment Manager Owner Retail Energy Code Company Change selection
Structure
SV00159
Flow structure for SV00159
ID Name Range Level Required
01A MPAN Cores Range: 1-* L1 Mandatory
MPAN Core Mandatory
Effective from Settlement Date {MSMTD} Mandatory
Meter COP Mandatory
Meter COP Issue Number
Conditions: Meter COP Issue Number

Meter COP Issue Number is Mandatory if the Meter CoP is associated to an issue number, or the data item must be Not Present if the Meter CoP is not associated to an issue number.

Complex Site Indicator Mandatory
Meter Equipment/Service Location
Conditions: Meter Equipment/Service Location

Meter Equipment/Service Location is Mandatory where further instructions are required to identify the meter position, the data item is Optional if further instructions additional to the Metering Point Location are not required.

System Voltage Mandatory
Number of Phases Mandatory
Event Indicator Mandatory
Additional Information
Conditions: Additional Information

Additional Information is Mandatory if Event Indicator value is Z, or the data item is Optional for any other value.

02A Outstation Details Range: 0-* L2
Conditions: Outstation Details

Outstation Details message collection is Mandatory if a meter is installed at the Metering Point; or message collection must be Not Present if no meter is installed at the Metering Point.

Outstation Id Mandatory
Outstation Type Mandatory
Modem Type Optional
Outstation Number of Channels Mandatory
Outstation Number of Dials Mandatory
Outstation PIN Optional
Outstation Username Level 1 Optional
Outstation Password Level 1 Optional
Outstation Username Level 2 Optional
Outstation Password Level 2 Optional
Outstation Username Level 3 Optional
Outstation Password Level 3 Optional
Reader Password Optional
Communications Method Mandatory
Communications Method B Optional
Dial In/ Dial Out Indicator Optional
Communications Address Optional
Communications Address B Optional
Baud Rate Optional
Communications Provider Optional
SIM Serial Number Optional
Sequence MPAN Core Optional
Sequence Outstation Id Optional
03A Meter Details Range: 0-* L2
Conditions: Meter Details

Meter Current Rating is Mandatory for whole current operated meters or Not Present for current transformer operated meters.

CT Ratio is Mandatory for current transformer operated meters or Not Present for whole current operated meters.

Meter Details message collection is Mandatory if a meter is installed at the Metering Point; or message collection must be Not Present if no meter is installed at the Metering Point.

Meter ID Mandatory
Manufacturers Make & Type Optional
Date of Meter Installation Mandatory
Meter Current Rating Optional
VT Ratio Optional
CT Ratio
Conditions: CT Ratio

CT Ratio is Mandatory for current transformer operated meters or Not Present for whole current operated meters.

Meter Details message collection is Mandatory if a meter is installed at the Metering Point; or message collection must be Not Present if no meter is installed at the Metering Point.

Phase/Wire Optional
Feeder Status Mandatory
Feeder Status Effective From Date Mandatory
Meter Asset Provider Id Mandatory
04A Meter Register Details Range: 1-* L3
Conditions: Meter Register Details

A Meter Register Details message collection is Mandatory for each active channel visible to the HHDC.

Meter Register Id Mandatory
Outstation Id Mandatory
Channel Number Mandatory
Pulse Multiplier Mandatory
Meter Register Multiplier Mandatory
Outstation Multiplier Mandatory
Measurement Quantity Id Mandatory
Number of Register Digits Mandatory
Associated Meter Id Optional
Associated Meter Register Id Optional
81C Meters Removed Range: 0-* L2
Conditions: Meters Removed

Meters Removed message collection is Mandatory if the message is generated following a meter removal or exchange event at the Metering Point; or message collection must be Not Present if generated for any other event.

Meter ID Mandatory
Date of Meter Removal Mandatory
Meter Asset Provider Id Mandatory