MM00217

Notification of MC/EAC/PC

Local Catalogue Reference
D0289
Message Version
2
Description
Establishes the Measurement Class for Half Hourly metered or unmetered supply. It also provides a Profile Class and EAC to allow the estimation of consumption.
Notes
EAC Details and Profile Class details must be populated on change of Measurement Class Details where recipient is the HHDC. Effective dates can not be earlier than the REGI date. It is anticipated this data flow would arrive at a similar time to the D0148 & the D0131 in the appointment life cycle. Where this flow is sent to the Meter Operator, only the Supplier and Measurement Class details should be populated (Groups 82B and 83B).
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00218 Name Notification of MC/EAC/PC Source Electricity Supplier Target Electricity Meter Equipment Manager Owner Balancing and Settlement Code Company Change selection
Structure
SV00218
Flow structure for SV00218
ID Name Range Level Required
82B MPAN Cores Range: 1-* L1 Mandatory
MPAN Core Mandatory
Effective from Settlement Date {REGI} Mandatory
83B Measurement Class Details Range: 1-1 L2 Mandatory
Measurement Class Id Mandatory
Effective from Settlement Date {MSMCDC} Mandatory
84B EAC Details Range: 0-0 L2
Estimated Annual Consumption Mandatory
Effective from Settlement Date {EACDC} Mandatory
85B Profile Class Details Range: 0-0 L2
Profile Class Id Mandatory
Effective from Settlement Date {MSPCDC} Mandatory