MM00256

Notification of Meter Information to MPAS

Local Catalogue Reference
D0312
Message Version
3
Description
Update MPAS with change to non-MPAS sourced data and the response
Notes
See Annex C for Flow Notes
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00256 Name Notification of Meter Information to MPAS Source Electricity Meter Equipment Manager Target Electricity Retail Data Agent Owner Retail Energy Code Company Change selection
Structure
SV00256
Flow structure for SV00256
ID Name Range Level Required
11D MPAN Core Range: 1-* L1 Mandatory
MPAN Core Mandatory
12D Meter Info Group Range: 0-* L2
Conditions: Meter Info Group

Where the Meter Type is prefixed with S1, S2 or 2, Meter Location is Mandatory. Meter Location is Null for all other Meter Types.

Where the Meter Type is prefixed with S1, S2 or 2, ESME ID is Mandatory. ESME ID is Null for all other Meter Types.

Where the Meter Type is prefixed with S1, S2 or 2, Number of Displayed Register Digits is Mandatory. Number of Displayed Register Digits is Null for all other Meter Types.

Meter Info Group is Mandatory for each meter installed at a metering point; message collection must be Not Present if no meters are installed.

Meter ID Mandatory
Meter Type Mandatory
Meter Asset Provider Id Mandatory
Date of Meter Installation Mandatory
Meter Location
Conditions: Meter Location

Where the Meter Type is prefixed with S1, S2 or 2, Meter Location is Mandatory. Meter Location is Null for all other Meter Types.

Meter Info Group is Mandatory for each meter installed at a metering point; message collection must be Not Present if no meters are installed.

Electricity Smart Meter Equipment (ESME ID)
Conditions: Electricity Smart Meter Equipment (ESME ID)

Where the Meter Type is prefixed with S1, S2 or 2, ESME ID is Mandatory. ESME ID is Null for all other Meter Types.

Meter Info Group is Mandatory for each meter installed at a metering point; message collection must be Not Present if no meters are installed.

Number of Displayed Register Digits
Conditions: Number of Displayed Register Digits

Where the Meter Type is prefixed with S1, S2 or 2, Number of Displayed Register Digits is Mandatory. Number of Displayed Register Digits is Null for all other Meter Types.

Meter Info Group is Mandatory for each meter installed at a metering point; message collection must be Not Present if no meters are installed.

13D Meters Removed Range: 0-* L2
Conditions: Meters Removed

Meters Removed message collection is Mandatory if the message is generated following a meter removal or exchange event at the Metering Point; or message collection must be Not Present if generated for any other event.

Meter ID Mandatory
Date of Meter Removal Mandatory
Meter Asset Provider Id Mandatory
Electricity Smart Meter Equipment (ESME ID) Optional
76M Sending Meter Operator Range: 0-0 L2
Meter Operator Id Not Present
77M Response Range: 0-0 L3
MOP Flow Response Code Not Present