MM00257

Meter Readings

Local Catalogue Reference
D0010
Message Version
2
Description
Cumulative readings and maximum demand readings.
Notes
NHH - This flow is for notification of validated/invalid non half-hourly meter readings and includes optional fields for any site visit check information. In Change of Supplier processes this flow can be used to communicate candidate Change of Supplier readings. In particular, the Supplier to Supplier instance is used to communicate unvalidated readings taken directly from smart meters. Additional processing rules for DDC enrolled smart meters are contained in Annex C. It is also required to pass any remotely taken reads to NHHDCs for use in the Change of Supplier process. For all other cases Supplier must utilise D0071 to send candidate reads to NHHDC. For the avoidance of doubt NHHDC will always confirm a Change of Supplier reading using D0086..Where an AMVLP (Asset Metering Virtual Lead Party) is involved, the MPAN Core must contain an AMSID (Asset Metering System Identifier) and not an MPAN. HH - The instances of the D0010 from MOP to Supplier and MOP to Distributor should only be used when the meter is Half-Hourly and the reading is either initial and/or final .The instance of the D0010 from Supplier to Distributor should only be used where readings are taken (or sourced) by the Supplier from smart meters.The flow D0086 must always reflect this current flow. Where confirming a reading received on a D0071 where Reading Type has been populated with the value O (Old Supplier's estimated CoS Reading) the NHHDC should populate the data item (Reading Type) with D to signify that the reading has been Deemed or Estimated and is in line with meter reading history. - Where an AMVLP (Asset Metering Virtual Lead Party) is involved, the MPAN Core must contain an AMSID (Asset Metering System Identifier) and not an MPAN.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00290 Name Meter Readings Source Half Hourly Data Collector Target Electricity Supplier Owner Balancing and Settlement Code Company Change selection
Structure
SV00290
Flow structure for SV00290
ID Name Range Level Required
026 MPAN Cores Range: 1-* L1 Mandatory
MPAN Core Mandatory
BSC Validation Status Mandatory
027 Site Visit Information Range: 0-* L2 Optional
Site Visit Check Code Mandatory
Additional Information Optional
028 Meter/Reading Types Range: 1-* L2 Mandatory
Meter ID Mandatory
Reading Type Mandatory
029 Site Visit Information Range: 0-* L3 Optional
Site Visit Check Code Mandatory
Additional Information Optional
030 Register Readings Range: 0-* L3 Optional
Meter Register Id Mandatory
Reading Date & Time Mandatory
Register Reading Mandatory
MD Reset Date & Time Optional
Number of MD Resets Optional
Meter Reading Flag Optional
Reading Method Mandatory
032 Meter Reading Validation Result Range: 0-1 L4
Conditions: Meter Reading Validation Result

Meter Reading Validation Result message collection is Mandatory if Meter reading Flag is F or Not Present if T.

Meter Reading Reason Code Mandatory
Meter Reading Status Mandatory
033 Site Visit Information Range: 0-* L4 Optional
Site Visit Check Code Mandatory
Additional Information Optional