MM00321

Half Hourly Metered Data for EMR

Local Catalogue Reference
D0357
Message Version
1
Description
Half Hourly metered data for use by the CM Settlement Services Provider in calculating CM data, and/ or by the CFD Settlement Services provider in calculating CFD data.
Notes
When constructing this flow, the HHDA or the SVAA will not necessarily know which MPAN Cores are relevant to the CM Settlement Services Provider, and which to the CFD Settlement Services Provider. The HHDA or SVAA should therefore send the data flow to one or the other (and rely upon arrangements put in place between the CFD and CM Settlement Services Providers to ensure that data is used for the correct purposes). In practice, this means populating the flow header with the Market Participant Id of either Settlement Service Provider (or with their shared Market Participant Id, if they have not been allocated separate Market Participant Ids).
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00321 Name Half Hourly Metered Data for EMR Source Half Hourly Data Aggregator Target Contract for Difference Settlement Services Provider Owner Balancing and Settlement Code Company Change selection
Structure
SV00321
Flow structure for SV00321
ID Name Range Level Required
19I Data File Additional Header Range: 1-1 L1 Mandatory
Settlement Date Mandatory
Settlement Code Mandatory
Run Type Code Mandatory
Run Number Mandatory
GSP Group Mandatory
20I Supplier Range: 1-* L1 Mandatory
Supplier Id Mandatory
21I EMR MPAN Cores Range: 1-* L2 Mandatory
MPAN Core Mandatory
Measurement Quantity Id Mandatory
Actual/Estimated Indicator Mandatory
22I Settlement Period EMR Metered Data Range: 46-50 L3
Conditions: Settlement Period EMR Metered Data

Number of Periods must be either 46,48,50

Settlement Period Id Mandatory
Period Metering System Metered Data Mandatory
Period EMR Line Loss Mandatory
23I Supplier Range: 0-0 L1
Supplier Id Mandatory
24I EMR MPAN Cores Range: 1-* L2 Mandatory
MPAN Core Mandatory
Measurement Quantity Id Mandatory
Actual/Estimated Indicator Mandatory
25I Settlement Period EMR Metered Data Range: 46-50 L3
Conditions: Settlement Period EMR Metered Data

Number of Periods must be either 46,48,50

Settlement Period Id Mandatory
Period Metering System Metered Data Mandatory
Period EMR Line Loss Mandatory