MM00359

BM Unit Aggregated Half Hour Demand Disconnection Data File

Local Catalogue Reference
D0378
Message Version
1
Description
Aggregated line loss adjusted HH disconnection volumes in a GSP Group by Supplier and BM Unit.
Notes
Where this flow is being sent to the Supplier, the flow will contain data for that Supplier only. The BM Unit Aggregated Half Hour Data File is output in ascending order by Supplier Id, BM Unit Id, Consumption Component Class Id and Settlement Period Id. This flow is sent alongside the D0298 but only for Settlement Dates which include Settlement Period/s affected by a Demand Control Event. The flow is only required in relation to Suppliers that have Metering Systems affected by a Demand Control Event. The Start Date and Time and End Date and Time represent the beginning and end of a Demand Control Event instructed by the Transmission Company.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00360 Name BM Unit Aggregated Half Hour Demand Disconnection Data File Source Half Hourly Data Aggregator Target Supplier Volume Allocation Agent Owner Balancing and Settlement Code Company Change selection
Structure
SV00360
Flow structure for SV00360
ID Name Range Level Required
76K Data File Additional Header Range: 1-1 L1 Mandatory
Settlement Date Mandatory
Settlement Code Mandatory
Run Type Code Mandatory
Run Number Mandatory
GSP Group Mandatory
77K Demand Control Event Details Range: 1-* L1 Mandatory
Demand Control Event ID Mandatory
Start Date and Time Mandatory
End Date and Time Mandatory
78K Supplier Range: 1-* L1 Mandatory
Supplier Id Mandatory
79K BM Unit Range: 1-* L2 Mandatory
BM Unit Id Mandatory
80K Consumption Component Class Range: 0-* L3 Optional
Consumption Component Class Id Mandatory
81K Settlement Period / Data Aggregator HH MSID Count Range: 0-* L4 Optional
Settlement Period Id Mandatory
Data Aggregator Disconnected HH MSID Count Mandatory
82K Aggregated BM Unit Demand Disconnection Energy Range: 0-1 L5
Conditions: Aggregated BM Unit Demand Disconnection Energy

If disconnected energy

Aggregated BM Unit Demand Disconnection Energy Mandatory
83K Aggregated BM Unit Demand Disconnection Line Losses Range: 0-1 L5
Conditions: Aggregated BM Unit Demand Disconnection Line Losses

If disconnection Line Loss

Aggregated BM Unit Demand Disconnection Line Losses Mandatory