MM20034

SMRS Notification of MTD Updates

Local Catalogue Reference
Message Version
11
Description
This interface is used by SMRS to notify the outcome of changes of Metering Technical Information to the Metering Service, and if successful other participants. For example, Meter Installations, Removals and Exchanges. This response also includes confirmation of other existing meter(s) installed at the MPAN, which were not impacted by the Metering Event.
Notes
Block R0 reports the Registration outcome of the Metering Services' request to update MTD, either Accepted or Rejected; where rejected the Status/Error Message field will provide more details. The content of the original IF-005 message is then replayed in the blocks below (i.e. no change in data structure). In cases where the requested update of MTD's has been successful Accepted AND there are other Meters active/Installed at the MPAN, details of each of the additional meter(s) installed will also be provided. This message is for the purpose of exchanging Meter Technical Details between participants, therefore, it is not relevent to UMSDS or UMSO as these Supplier Agents are only able to support Unmetered Sites.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV20383 Name MeterInstall Source Supplier Meter Registration Service Target Owner Retail Energy Code Company Change selection
Structure
SV20383
Flow structure for SV20383
ID Name Range Level Required
S0 Transactional Info Range: 1-1 L1 Mandatory
Interface ID Mandatory
Schema Version Mandatory
Event Code Mandatory
S1 Sender Info Range: 1-1 L1 Mandatory
Environment Tag Mandatory
SubText Optional
Sender Unique Reference Mandatory
Sender Timestamp Mandatory
(Participant) Sender DIP ID Mandatory
Sender Role ID Mandatory
Sender Correlation ID Optional
Connection Provider DIP ID Optional
D0 Transactional Info - DIP Set Range: 1-1 L1 Mandatory
DIP Transaction ID Mandatory
DIP TimeStamp Mandatory
Publication ID Mandatory
DIP Correlation ID Optional
Replay Indicator Mandatory
Msg Service Ticket URL Optional
A0 Addressing Range: 0-1 L1
Conditions: Addressing

Optional for non-Primary Routing

DIP IDs Primary Recipients Mandatory
DIP ID Secondary Recipients Mandatory
DIP Roles / IDs Always Receipient ID Mandatory
Unnamed collection Range: 0-0 L1 Null
Unnamed collection Range: 0-0 L1 Null
M0 MPAN Range: 1-1 L1 Mandatory
MPAN Core Mandatory
Distributor DIP ID Mandatory
GSP Group Id Mandatory
R0 Response Range: 1-1 L1 Mandatory
Response Code Mandatory
Response Message Conditional
B033 New/Revised Meter Information Range: 1-1 L1 Mandatory
Meter ID Mandatory
Modified Meter ID Optional
Meter Type Mandatory
Manufacturers Make & Type Optional
Electricity Smart Meter Equipment (ESME ID) Conditional
Meter Location Mandatory
Number of Register Digits Conditional
Meter Installation Date / Time Mandatory
B034 Meter MAP Info Range: 1-1 L2 Mandatory
Meter Asset Provider Id Mandatory
Meter Asset Provider Effective From Date Mandatory
B039 Removed Meter Information Range: 0-0 L1 Optional
Meter ID (Removed) Mandatory
Meter Removal Date / Time Optional
B030 MPAN IHD Info Range: 0-1 L1
Conditions: MPAN IHD Info

May be provided for [MeterInstall]

In Home Display (IHD) Install Status Mandatory
IHD Status EffectiveFrom Date Mandatory
B074 MPAN Existing Meter Info Range: 0-* L1
Conditions: MPAN Existing Meter Info

Mandatory if additional Meters are Installed

Meter ID Mandatory
Meter Type Mandatory
Manufacturers Make & Type Optional
Electricity Smart Meter Equipment (ESME ID)
Conditions: Electricity Smart Meter Equipment (ESME ID)

Mandatory if additional Meters are Installed

Meter Location Mandatory
Number of Register Digits
Conditions: Number of Register Digits

Mandatory if additional Meters are Installed

Meter Installation Date / Time Mandatory
B075 MPAN Existing Meter MAP Info Range: 1-1 L2
Conditions: MPAN Existing Meter MAP Info

Most recent record only

Meter Asset Provider Id Mandatory
Meter Asset Provider Effective From Date Mandatory