Help
This page shows the Flow Structure for one Market Message, including its Scenario Variants and the REC Data Specification version it belongs to.
MM20035
MTD Updates to SMRS
Select version
Latest
- Local Catalogue Reference
- Message Version
- 11
- Description
- This interface is used by Metering Services to notify any changes required to Metering Technical Information, to the SMRS For example, Meter Installations, Removals and Exchanges. The interface also allows for corrections to the currently installed meter & the historical record of installed metering assets.
- Notes
- Only the Appointed Metering Service, and for a small window (10 days) to allow for delayed notification of field activities the previously appointed Metering Service; and an incoming Metering Service with a Prospective 'SEG' type appointment may send an IF-005 and update metering details. The [MeterUpdate] and [MeterHistoryUpdate] may only ever be used by the Appointed Metering Service. Interface Design assumes that two separate meters with the same 'Meter ID' cannot be installed at the same time. IHD Information - Suppliers are obligated to capture this information. This is usually shared between the MS & Supplier via a bespoke exchange of data and updated by the Supplier into Registration. Data items are included here as a possible replacement of that bespoke exchange of information. The update of if information via this interface shall have exactly the same effect in the Registration System as if the Supplier had provided the information via IF-025. On an exchange the IHD and MAP blocks need only be provided for the newly installed meter. For information - Meter Certification information is not included and is managed separately. Energy Direction is not included here as this is set by the LDSO at the point of MPAN creation. Meter Energisation Status is also not included as it is managed using MHHS-IF-008. If the Metering Service discovers a mismatch in Energisation Status, for example during a site visit, then he should initiate the 'Change of Energisation Status' process. Connection Type and Effective From Date information is not included in this interface as these are data items that are maintained by the LDSO. Where, the Metering Service believes the Connection Type to be incorrect they should initiate the processes to have this changed by the LDSO. The Design Team have publsihed an IF-005 Use Case Guide for further information on how to use Update and History Update Event Codes. Following DRG decision - when using the MeterUpdate & MeterHistoryUpdate events it shall only be possible to update details of the existing MAP.
| Variant ID | Name | Source | Target | Owner | Actions |
|---|---|---|---|---|---|
| Variant ID SV20718 | Name MeterUpdate | Source Metering Service | Target | Owner Retail Energy Code Company | Change selection |
Structure
SV20718
| ID | Name | Range | Level | Required |
|---|---|---|---|---|
| S0 | Transactional Info | Range: 1-1 | L1 |
|
| Interface ID |
|
|||
| Schema Version |
|
|||
| Event Code |
|
|||
| S1 | Sender Info | Range: 1-1 | L1 |
|
| Environment Tag |
|
|||
| SubText | Optional | |||
| Sender Unique Reference |
|
|||
| Sender Timestamp |
|
|||
| (Participant) Sender DIP ID |
|
|||
| Sender Role ID |
|
|||
| Sender Correlation ID | Optional | |||
| Connection Provider DIP ID | Optional | |||
| D0 | Transactional Info - DIP Set | Range: 1-1 | L1 |
|
| DIP Transaction ID |
|
|||
| DIP TimeStamp |
|
|||
| Publication ID |
|
|||
| DIP Correlation ID | Optional | |||
| Replay Indicator |
|
|||
| Msg Service Ticket URL | Optional | |||
| A0 | Addressing | Range: 0-1 | L1 | |
| DIP IDs Primary Recipients |
|
|||
| DIP ID Secondary Recipients |
|
|||
| DIP Roles / IDs Always Receipient ID |
|
|||
| Unnamed collection | Range: 0-0 | L1 | Null | |
| Unnamed collection | Range: 0-0 | L1 | Null | |
| M0 | MPAN | Range: 1-1 | L1 |
|
| MPAN Core |
|
|||
| Distributor DIP ID |
|
|||
| GSP Group Id |
|
|||
| B033 | New/Revised Meter Information | Range: 1-1 | L1 |
|
| Meter ID |
|
|||
| Modified Meter ID | Optional | |||
| Meter Type |
|
|||
| Manufacturers Make & Type | Optional | |||
| Electricity Smart Meter Equipment (ESME ID) | Conditional | |||
| Meter Location |
|
|||
| Number of Register Digits | Conditional | |||
| Meter Installation Date / Time |
|
|||
| B034 | Meter MAP Info | Range: 0-* | L2 | Optional |
| Meter Asset Provider Id |
|
|||
| Meter Asset Provider Effective From Date |
|
|||
| B039 | Removed Meter Information | Range: 0-1 | L1 | Optional |
| Meter ID (Removed) |
|
|||
| Meter Removal Date / Time | Optional | |||
| B030 | MPAN IHD Info | Range: 0-1 | L1 | |
| In Home Display (IHD) Install Status |
|
|||
| IHD Status EffectiveFrom Date |
|