MM20075

MDR Request / Provide Meter Reading

Local Catalogue Reference
Message Version
11
Description
MDR Provide Meter Reading(s) to SDS
Notes
The following event codes are 'requests' and only require block M01 and optional block B060: [MDRInstantaneous] = Request Instaneous Recovery of Cumulative Register Reading (Reponse via IF-065) [MDRTOU] = Request Recovery of TOU Registers (Midnight Read Log) for Settlement Date Specified (Response via IF-065) [MDRConsumption] = Request Recovery of HH Consumption Log for Settlement Date Specified (Reponse via IF-064)
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV20769 Name MDRInstantaneous Source Smart Data Service Target Owner Balancing and Settlement Code Company Change selection
Structure
SV20769
Flow structure for SV20769
ID Name Range Level Required
S0 Transactional Info Range: 1-1 L1 Mandatory
Interface ID Mandatory
Schema Version Mandatory
Event Code Mandatory
S1 Sender Info Range: 1-1 L1 Mandatory
Environment Tag Mandatory
SubText Optional
Sender Unique Reference Mandatory
Sender Timestamp Mandatory
(Participant) Sender DIP ID Mandatory
Sender Role ID Mandatory
Sender Correlation ID Optional
Connection Provider DIP ID Optional
D0 Transactional Info - DIP Set Range: 1-1 L1 Mandatory
DIP Transaction ID Mandatory
DIP TimeStamp Mandatory
Publication ID Mandatory
DIP Correlation ID Optional
Replay Indicator Mandatory
Msg Service Ticket URL Optional
A0 Addressing Range: 0-1 L1
Conditions: Addressing

Optional for non-Primary Routing

DIP IDs Primary Recipients Mandatory
DIP ID Secondary Recipients Mandatory
DIP Roles / IDs Always Receipient ID Mandatory
M0 MPAN Range: 1-1 L1 Mandatory
MPAN Core Mandatory
Distributor DIP ID Mandatory
GSP Group Id Mandatory
B076 MDR Cumulative Reading Information Range: 0-* L1 Optional
Meter ID Mandatory
Cumulative Register Reading Mandatory
Cumulative Register Reading Date/Time Mandatory
B065 Meter Configurable Register Reading Range: 0-* L1 Optional
Meter ID Mandatory
Configurable Register Reading Date Mandatory
Configurable Register ID Mandatory
Configurable Register Reading Mandatory
B077 MDR Request Reference Date Range: 0-1 L1 Conditional
MDR Reference Date Mandatory
B060 Additional Information Range: 0-1 L1 Optional
Additional Information Mandatory