MM90045

Supply Meter Point Synchronisation

Local Catalogue Reference
RECM_SN_CSS01100
Message Version
1
Description
Supply Meter Point Synchronisation
Notes
Response to this message will be in the format of MM90071 ' Standard Response Body. See Business Data Validation Rules document for details of the potential status codes to be returned against each Scenario Variant
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV90367 Name Supply Meter Point Synchronisation - Gas - Provision Source Gas Retail Data Agent Target Central Switching Service Owner Retail Energy Code Company Change selection
Structure
SV90367
Flow structure for SV90367
ID Name Range Level Required
Body - SV90148 Range: 1-1 L1 Mandatory
mpxn Mandatory
networkProvisionMpid Mandatory
networkProvisionRole Mandatory
networkProvisionFromDate Mandatory
rmpStatus Mandatory
rmpStatusFromDate Mandatory
timeBoundaryAlignmentStatus Optional
dccServiceInd Optional
mplAddress - SV90148 Range: 1-1 L2
Conditions: mplAddress - SV90148

Please reference Address Population Rules.

deliveryPointAlias Optional
subBuildingNameOrNumber Optional
buildingName Optional
buildingNumber Optional
dependentThoroughfare Optional
thoroughfare Optional
doubleDependentLocality Optional
dependentLocality Optional
postTown Optional
county Optional
postcode Optional
uprn Optional
assetOwnershipMaps - SV90148 Range: 0-1 L2 Conditional
mpid Mandatory
role Mandatory