ERDS Service Definition timezone correction

  • 1
    Initial Assessment
  • 2
    Solution Development
  • 3
    Consultation
  • 4
    Decision
  • 5
    Awaiting Implementation
  • 6
    Implemented
Step 6 of 6
Implemented
Summary
This change seeks to specify timezones within the ERDS Service Definition. For example: Data received by the ERDA shall be included within the ERDS Total Daily Processing on the basis that all data received prior to 23:00hrs is made available to the SMRA, EES Provider or CSS Provider (as applicable) by 06:00hrs the following Working Day. Data received after 23:00hrs will be made available to the SMRA, EES Provider or CSS Provider (as applicable) by the second Working Day

Latest update and next planned activity

Date of latest update
Latest Update
This Change Proposal was implemented as part of the 7 November 2025 REC Release.

Impacts Overview

Impacted Consumers
Electricity
Impacted REC Parties and Market Participants
Distribution Network Operator
Priority and rationale
Standard

Priority last updated on 29 May 2026

Solution development

Problem Statement
The ERDS Service Definition does not specify the time with a specified time zone. This has led to some instances of MPRS close of day running at 22:00GMT instead of 23:00GMT. A confirmation of time zone is required within the ERDS Service Definition to negate any confusion or delays in flow processing and systems becoming misaligned.
Proposed solution summary
  1. As a Supplier, I want to have confidence that the data in the systems is aligned and accurate.
  2. As ERDS Provider, I want to be able to provide accurate and appropriately labelled data that can be aligned with data from other systems.

No documents available.

Change Plan

Change Proposal Plan and Impact Assessment Report Published

Completed

Start:

22 Aug 2022

Due:

18 Jun 2024

Completion:

18 Jun 2024

Change report and Consultation issued

Completed

Start:

18 Jun 2024

Due:

28 Jun 2024

Completion:

27 Jun 2024

Consultation closed

Completed

Start:

28 Jun 2024

Due:

19 Jul 2024

Completion:

19 Jul 2024

Responsible Committee decision

Completed

Start:

19 Jul 2024

Due:

28 Aug 2024

Completion:

28 Aug 2024

Appeal Window Closure

Not Started

Start:

28 Aug 2024

Due:

12 Sep 2024

Completion:

Original submission

Change details

Daniel Tadecicco - St Clements Services
22 Aug 2022

Change details

ERDS Service Definition timezone correction
The ERDS Service definition does not specify any timezones for example: Data received by the ERDA shall be included within the ERDS Total Daily Processing on the basis that all data received prior to 23:00hrs is made available to the SMRA, EES Provider or CSS Provider (as applicable) by 06:00hrs the following Working Day. Data received after 23:00hrs will be made available to the SMRA, EES Provider or CSS Provider (as applicable) by the second Working Day
Due to the differences in System timezone, CSS and UKLINK in Localtime and EES, DSP and MPRS in GMT (UTC0) there was some confusion at Go Live when the end of day is in MPRS (ERDA) as the Schedule only specifies the 23:00 time and not the Timezone. This lead to some instances of MPRS close of day running at 22:00GMT instead of 23:00GMT.
The ERDS Service Definition should be amended to add the GMT Timezone to any timebased statements for example: Daily Processing on the basis that all data received prior to 23:00hrs GMT is made available to the SMRA, EES Provider or CSS Provider (as applicable) by 06:00hrs the following Working Day. Data received after 23:00hrs GMT will be made available to the SMRA, EES Provider or CSS Provider (as applicable) by the second Working Day
-

Impacts

Electricity
Billing accuracy
All DTS flows must be in GMT, this is a S3P4V1-7_User_File_Design_S Requirement. Data Aggregators require D0209s to be in GMT. If the MPRS (ERDA) end of day closes an hour earlier than expected, it can lead to a delay in flow processing and systems becoming misaligned.
No details provided
Electricity Retail Data Service Definition
No details provided
-
No details provided
-
No details provided
-
No details provided
-
No details provided
-
Distribution Network Operators
-
No details provided
-
-
No details provided

Priority & timing

No
-
-
-
No details provided
-

Activity

Proposed solution summary changed to As a Supplier, I want to have confidence that the data in the systems is aligned and accurate.As ERDS Provider, I want to be able to provide accurate and appropriately labelled data that can be aligned with data…
Show more
Status has been changed to Implemented.
Implementation Date has been updated to 07 Nov 2025.
beth.brown, Orphaned SME: Lead Assurance Analyst have been allocated as SME.