MM00139

Request and Information for Revenue Protection Investigation

Local Catalogue Reference
D0238
Message Version
1
Description
A request/confirmation that an investigation into a suspected metering tampering case should be carried out by the Revenue Protection Service and provision of background information to assist the investigation.
Notes
Where a meter change or agent change has occurred during the historical readings period this should be highlighted within the readings through 'type' and 'date and time'. Though all of the address data items included in this flow are defined within the structure as being optional, the address itself is mandatory and must be included in the flow. The use of any individual address item cannot be made mandatory as, in the absence of an agreed address structure for all flows, an address may be constructed from any combination of the Address Line and Postcode items.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00139 Name Request and Information for Revenue Protection Investigation Source Electricity Supplier Target Revenue Protection Service Owner Retail Energy Code Company Change selection
Structure
SV00139
Flow structure for SV00139
ID Name Range Level Required
627 MPAN Cores Range: 1-* L1
Conditions: MPAN Cores

Please reference Address Population Rules.

MPAN Core Mandatory
Meter Operator Id Mandatory
Customer Name Optional
Address Line 1 Optional
Address Line 2 Optional
Address Line 3 Optional
Address Line 4 Optional
Address Line 5 Optional
Address Line 6 Optional
Address Line 7 Optional
Address Line 8 Optional
Address Line 9 Optional
Metering Point Postcode Optional
Customer Password Optional
Supplier Contact Name Optional
Supplier Contact Telephone Number Optional
Revenue Protection Priority Level Mandatory
Appointment Date Optional
Earliest Appointment Time Optional
Latest Appointment Time Optional
Tampering Code Mandatory
Tampering Report Source Mandatory
Tampering Report Date Mandatory
Additional Information Optional
628 Associated MPANs Range: 0-* L2 Optional
Associated MPAN Mandatory
629 Meter Details Range: 1-* L2 Mandatory
Meter ID Mandatory
Manufacturers Make & Type Mandatory
Meter Type Mandatory
Meter Location Mandatory
Timing Device Id (Serial Number) Optional
Date of Meter Installation Optional
Last Reading/Inspected Date Mandatory
Date Customer Took Responsibility for Supply Optional
Energisation Status Mandatory
Disconnected for Non-Payment Status Mandatory
630 Meter Register Details per Meter Range: 1-* L3 Mandatory
Meter Register Id Mandatory
631 Reading Dates Covering Two Years Range: 0-* L4 Optional
Reading Date & Time Optional
Register Reading Optional
Reading Type Optional