MM00220

Notification of Register Readings on Change of Measurement Class coincident with Change of Supplier

View Latest version
Local Catalogue Reference
D0291
Message Version
1
Description
HHMO notifies the NHHMO of the register readings on a change of measurement class from NHH to HH.
Notes
The HH Meter Operator may remove or reconfigure the NHH Metering System on a change of measurement class, however, they may not be aware of the various register mappings that need to be applied. The HHMO is therefore required to pass any/all of the register readings along with register details to the NHHMO to enable them to translate the values given into readings that may be used by the NHHDC. Where the NHH meter is not present, or final readings were not obtained the HHMO needs to provide this information to the NHHMO.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV00220 Name Notification of Register Readings on Change of Measurement Class coincident with Change of Supplier Source Electricity Meter Equipment Manager Target Electricity Meter Equipment Manager Owner Balancing and Settlement Code Company Change selection
Structure
SV00220
Flow structure for SV00220
ID Name Range Level Required
10C Non Half Hourly Metering System Range: 1-* L1
Conditions: Non Half Hourly Metering System

Please reference Address Population Rules.

MPAN Core Mandatory
CoS and Coincident CoMC Indicator Mandatory
Effective from Settlement Date {REGI} for New Supplier Mandatory
Address Line 1 Optional
Address Line 2 Optional
Address Line 3 Optional
Address Line 4 Optional
Address Line 5 Optional
Address Line 6 Optional
Address Line 7 Optional
Address Line 8 Optional
Address Line 9 Optional
Metering Point Postcode Optional
Date of Action Mandatory
11C Non Half Hourly Meter not present Range: 0-* L2
Conditions: Non Half Hourly Meter not present

Non Half Hourly Meter not present message collection is Mandatory if no meter is installed or message collection must be Not Present if a meter is installed.

Site Visit Check Code Optional
Additional Information Optional
12C Non Half Hourly Meter details Range: 0-* L2
Conditions: Non Half Hourly Meter details

Non Half Hourly Meter details message collection is Mandatory if a meter is installed at the Metering Point; or the message collection must be Not Present if no meter installed.

Meter ID Mandatory
Date of Meter Removal Optional
Site Visit Check Code Optional
Additional Information Optional
13C Non Half Hourly Meter Registers Range: 0-* L3 Optional
Register Description Mandatory
Register Reading Mandatory
Reading Date & Time Mandatory