MM20037

Notification to New Supplier of Site Information

View Latest version
Local Catalogue Reference
Message Version
11
Description
Following notification of a potential/pending Switch from CSS, SMRS issue this message to the incoming Supplier. Purpose of this message is to advise the incoming Supplier of Site Information so that the Supplier can determine the correct Supplier Agents to appoint (equivilent to D217/D260 in pre-MHHS process).
Notes
Design Team recognise that this area of the Design is subject to impact by RC0040 The MHHS Design is such that it is possible that the SMRS may not always be able to provide details of 'Incumbent Supplier Agents'. Obviously this will be the case on Initial Registration, but it may also be in cases where the Previous Supplier has been unable to successfully complete Supplier Agent Appointment(s) prior to the next switch then taking place. 'Annual Consumption' will not be calculated until the first consumption is recoreded in Settlements - therefore the Annual Consumption section will again not be populated for newly created MPANs.
Scenario Variants
Variant ID Name Source Target Owner Actions
Variant ID SV20722 Name GainMPANInfo Source Supplier Meter Registration Service Target Owner Balancing and Settlement Code Company Change selection
Structure
SV20722
Flow structure for SV20722
ID Name Range Level Required
S0 Transactional Info Range: 1-1 L1 Mandatory
Interface ID Mandatory
Schema Version Mandatory
Event Code Mandatory
S1 Sender Info Range: 1-1 L1 Mandatory
Environment Tag Mandatory
SubText Optional
Sender Unique Reference Mandatory
Sender Timestamp Mandatory
(Participant) Sender DIP ID Mandatory
Sender Role ID Mandatory
Sender Correlation ID Optional
Connection Provider DIP ID Optional
D0 Transactional Info - DIP Set Range: 1-1 L1 Mandatory
DIP Transaction ID Mandatory
DIP TimeStamp Mandatory
Publication ID Mandatory
DIP Correlation ID Optional
Replay Indicator Mandatory
Msg Service Ticket URL Optional
A0 Addressing Range: 0-1 L1
Conditions: Addressing

Optional for non-Primary Routing

DIP IDs Primary Recipients Mandatory
DIP ID Secondary Recipients Mandatory
DIP Roles / IDs Always Receipient ID Mandatory
Unnamed collection Range: 0-0 L1 Null
Unnamed collection Range: 0-0 L1 Null
M0 MPAN Range: 1-1 L1 Mandatory
MPAN Core Mandatory
Distributor DIP ID Mandatory
GSP Group Id Mandatory
B013 CSS Registration Request ID Range: 1-1 L1 Mandatory
registrationId Mandatory
B005 Incumbent/Outgoing Service Providers Range: 0-1 L1 Optional
Current Metering Service DIP ID
Conditions: Current Metering Service DIP ID

Where available in SMRS

Current Metering Service MPID
Conditions: Current Metering Service MPID

Where available in SMRS

Current Data Service DIP ID
Conditions: Current Data Service DIP ID

Where available in SMRS

Current Data Service MPID
Conditions: Current Data Service MPID

Where available in SMRS

B006 Customer Direct Contracts Range: 0-1 L1
Conditions: Customer Direct Contracts

Mandatory if Customer Direct Contract is Registered/Recorded

Customer Direct Contract Metering Service Mandatory
Customer Direct Contract MS DIP ID
Conditions: Customer Direct Contract MS DIP ID

Mandatory if Customer Direct Contract is Registered/Recorded

Customer Direct Contract Data Service Mandatory
Customer Direct Contract DS DIP ID
Conditions: Customer Direct Contract DS DIP ID

Mandatory if Customer Direct Contract is Registered/Recorded

B022 MPAN Address Range: 1-1 L1 Mandatory
Metering Point Postcode Optional
Address Line 1 Optional
Address Line 2 Optional
Address Line 3 Optional
Address Line 4 Optional
Address Line 5 Optional
Address Line 6 Optional
Address Line 7 Optional
Address Line 8 Optional
Address Line 9 Optional
B023 MPAN Connection Info Range: 1-1 L1 Mandatory
Connection Type Mandatory
Connection Type Effective From Date Mandatory
Direction of Energy Flow Mandatory
Metered Indicator Mandatory
B024 MPAN DUOS Tariff ID Range: 1-1 L1 Mandatory
DUoS Tariff ID Mandatory
DUoS Tariff ID Effective From Date Mandatory
B025 MPAN Energisation Status Range: 1-1 L1 Mandatory
Energisation Status Mandatory
Energisation Status Effective From Date Mandatory
B026 MPAN Market Segment Range: 1-1 L1 Mandatory
Market Segment Indicator Mandatory
Market Segment Indicator Effective From Date Mandatory
B027 Assumed Annual Consumption Range: 0-1 L1
Conditions: Assumed Annual Consumption

Mandatory where available in SMRS

Annual Consumption Mandatory
Annual Consumption EffectiveFrom Date Mandatory
Annual Consumption Quality Indicator Mandatory
B029 DCC Enrolment Status Range: 0-1 L1
Conditions: DCC Enrolment Status

Mandatory only for Smart Meters

DCC Service Flag Mandatory
DCC Effective From Date Mandatory
B030 MPAN IHD Info Range: 0-1 L1 Optional
In Home Display (IHD) Install Status Mandatory
IHD Status EffectiveFrom Date Mandatory
B031 SMSO Info Range: 0-1 L1 Optional
Smart Metering System Operator (SMSO) Mandatory
SMSO EffectiveFrom Date Mandatory
B032 MPAN Legacy Info Range: 0-1 L1 Conditional
Profile Class Id
Conditions: Profile Class Id

Mandatory for Traditional Meters / Optional for other Meters or where not available in SMRS

Profile Class Effective From Date
Conditions: Profile Class Effective From Date

Mandatory for Traditional Meters / Optional for other Meters or where not available in SMRS

Standard Settlement Configuration (SSC) Id
Conditions: Standard Settlement Configuration (SSC) Id

Mandatory for Traditional Meters / Optional for other Meters or where not available in SMRS

SSC EffectiveFromDate
Conditions: SSC EffectiveFromDate

Mandatory for Traditional Meters / Optional for other Meters or where not available in SMRS

B074 MPAN Existing Meter Info Range: 0-* L1
Conditions: MPAN Existing Meter Info

Mandatory if Metering Installed

Meter ID Mandatory
Meter Type Mandatory
Manufacturers Make & Type Optional
Electricity Smart Meter Equipment (ESME ID)
Conditions: Electricity Smart Meter Equipment (ESME ID)

Mandatory if Metering Installed

Meter Location Mandatory
Number of Displayed Register Digits
Conditions: Number of Displayed Register Digits

Mandatory if Metering Installed

Meter Installation Date / Time Mandatory
B075 MPAN Existing Meter MAP Info Range: 1-1 L2
Conditions: MPAN Existing Meter MAP Info

Most recent record only

Meter Asset Provider Id Mandatory
Meter Asset Provider Effective From Date Mandatory
B035 Linked Import / Export MPAN Range: 0-* L1
Conditions: Linked Import / Export MPAN

Mandatory if Linked MPAN Exists

Associated Import / Export MSID Mandatory
Associated MPAN Energy Direction Mandatory
Import/Export MPAN Supplier DIP ID
Conditions: Import/Export MPAN Supplier DIP ID

Mandatory if Linked MPAN Exists

Import/Export MPAN Supplier MPID
Conditions: Import/Export MPAN Supplier MPID

Mandatory if Linked MPAN Exists

B036 Linked Import/Export Meter Details Range: 0-* L2
Conditions: Linked Import/Export Meter Details

Mandatory for each Meter Provided

Meter ID Mandatory
Meter Type Mandatory
Manufacturers Make & Type Optional
Electricity Smart Meter Equipment (ESME ID)
Conditions: Electricity Smart Meter Equipment (ESME ID)

Mandatory for each Meter Provided

Meter Location Mandatory
Number of Displayed Register Digits
Conditions: Number of Displayed Register Digits

Mandatory for each Meter Provided

Meter Installation Date / Time Mandatory
B075 MPAN Existing Meter MAP Info Range: 1-1 L3
Conditions: MPAN Existing Meter MAP Info

Most recent record only

Meter Asset Provider Id Mandatory
Meter Asset Provider Effective From Date Mandatory
B037 Related MPAN(s) Range: 0-* L1 Optional
Primary MPAN
Conditions: Primary MPAN

B037 repeated for each Related MPAN that exists

Secondary MPAN
Conditions: Secondary MPAN

B037 repeated for each Related MPAN that exists

B038 Related MPAN Meter Details Range: 0-* L2
Conditions: Related MPAN Meter Details

B038 repeated for each Meter / MAP History Pair

Meter ID Mandatory
Meter Type Mandatory
Manufacturers Make & Type Optional
Electricity Smart Meter Equipment (ESME ID)
Conditions: Electricity Smart Meter Equipment (ESME ID)

B038 repeated for each Meter / MAP History Pair

Meter Location Mandatory
Number of Displayed Register Digits
Conditions: Number of Displayed Register Digits

B038 repeated for each Meter / MAP History Pair

Meter Installation Date / Time Mandatory
B075 MPAN Existing Meter MAP Info Range: 1-1 L3
Conditions: MPAN Existing Meter MAP Info

Most recent record only

Meter Asset Provider Id Mandatory
Meter Asset Provider Effective From Date Mandatory